Increased physiological arousal relates to less monitoring with neutral valence¶
Claim · All claims
Evidence · 1 study · associationalr1·q3
Currency · newest study 2021 · not yet checked against its sources · not reviewed by a person
Subclaims¶
Reading the evidence codes
q is the design tier, i the impact, n the sample, and the kind with its r
the rigour judged within that kind: what each code means.
This claim: no standardized effect is recorded in observations/ for it yet, so no benchmark reading is possible.
q3 i? An increase in physiological arousal is related to less monitoring with neutral valence. → Haataja 2021
Evidence¶
Haataja 2021¶
Haataja, E., Malmberg, J., Dindar, M., & Järvelä, S. (2021). The pivotal role of monitoring for collaborative problem solving seen in interaction, performance, and interpersonal physiology. Metacognition and Learning, 17, 241–268. https://doi.org/10.1007/s11409-021-09279-3
q3 · i? · associational · r1
GEE model predicting neutral valence monitoring duration from physiological measures in 19 groups. The tonic EDA slope was a "significant negative predictor, meaning that an increase in arousal was related to less monitoring interactions with neutral valence."
"the model predicting monitoring with neutral valence included the tonic EDA slope as a significant negative predictor, meaning that an increase in arousal was related to less monitoring interactions with neutral valence"
Discussion¶
Related Claims¶
- Increased physiological arousal and higher physiological synchrony relate to more monitoring with negative valence — related
- Higher physiological synchrony relates to less monitoring with positive valence — related
- Individual participation in monitoring processes was consistent with physiological arousal, suggesting an observable indicator of participation — related
- Effortful regulation is maximized at moderate levels of emotional and physiological reactivity and declines at very low or very high levels — related
- Higher equality of participation in monitoring interactions and more monitoring with positive valence predict better collaborative task performance — related
- Neither physiological arousal nor physiological synchrony predicts equality of participation in monitoring interactions — related
Page metadata
| Field | Value |
|---|---|
type |
claim |
id |
arousal-negative-predictor-neutral-valence |
title |
Increased physiological arousal relates to less monitoring with neutral valence |
description |
Increased physiological arousal relates to less monitoring with neutral valence |
status |
review |
evidence_strength |
moderate |
newest_evidence |
2021 |
generated |
by process:wiki-ingest on 2026-10-18 |
trust |
unverified — no one has confirmed this page's content |
sources |
1 — haataja-2021 |
Frontmatter is the page's machine-readable record — see the Schema & Guide.