Claims

Concurrent calibration yielded consistently lower and less fluctuating scale score means than separate calibration with chain or simultaneous equating, especially for older tests

Claim · All claims
Evidence · 1 study · design r2 · q2
Currency · newest study 2017 · not yet checked against its sources · not reviewed by a person · overdue for a recheck since 2020: tool and model accuracy changes quickly

Subclaims

Reading the evidence codes

q is the design tier, i the impact, n the sample, and the kind with its r the rigour judged within that kind: what each code means.

This claim: no standardized effect is recorded in observations/ for it yet, so no benchmark reading is possible.

q2 i? Scale score means from concurrent calibration (CR) were relatively less fluctuated and consistently lower than those from the separate-calibration equating methods (CH and SM), with the difference largest for tests prior to 2002F. → Jungnam Kim 2017

Evidence

Jungnam Kim 2017

Jungnam Kim, Furong Gao, & Dong-In Kim. (2017). Robust IRT Scaling: Considerations in constructing item bank from tests across years. Paper presented at the annual meeting of the National Council on Measurement in Education, San Antonio, TX. https://www.nwea.org/research/publication/robust-irt-scaling-considerations-in-constructing-item-bank-from-tests-across-years/

q2 · i? · design · r2

Results section comparison of mean scale scores across 45 administrations (Figure 4; Tables 2-3). For example, 1992F summed-scoring means were 513.72 (CH_S), 514.37 (SM_S), and 424.92 (CR_S), showing the CR means were "consistently lower."

"With the CR method, the score means across years were relatively less fluctuated and consistently lower, more so with the older tests, than those from the separate calibration methods."

Discussion

Page metadata
Field Value
type claim
id concurrent-calibration-lower-scale-means-older-tests
title Concurrent calibration yielded consistently lower and less fluctuating scale score means than separate calibration with chain or simultaneous equating, especially for older tests
description Concurrent calibration yielded consistently lower and less fluctuating scale score means than separate calibration with chain or simultaneous equating, especially for older tests
status review
evidence_strength moderate
newest_evidence 2017
recheck_by 2020
generated by process:wiki-ingest on 2026-10-08
trust unverified — no one has confirmed this page's content
sources 1 — jungnam-kim-2017

Frontmatter is the page's machine-readable record — see the Schema & Guide.