The leakage manipulation fires: ConvTutor leaks far more than PedTutor on the primary base, while probe accuracy saturates and cannot distinguish conditions¶
Claim · All claims
Evidence · 1 study · causalr2·q3
Currency · newest study 2026 · not yet checked against its sources · not reviewed by a person
Subclaims¶
Reading the evidence codes
q is the design tier, i the impact, n the sample, and the kind with its r
the rigour judged within that kind: what each code means.
This claim: no standardized effect is recorded in observations/ for it yet, so no benchmark reading is possible.
q3 i? ConvTutor's mean per-session leakage fraction is 43.0% against 6.4% for PedTutor (P1 supported). → Shuyi Fan 2026
Evidence¶
Shuyi Fan 2026¶
Shuyi Fan, Boyuan Deng, Mengyu Xu, Jiale Liu, Hongyang Zhang, Qiaoxin Yang, Chongyang Gao. (2026). Rethinking LLM-Judged Helpfulness as a Pedagogy Signal: A Pre-Registered Audit Across Tutor Models. arXiv. https://arxiv.org/abs/2607.28128 doi:10.48550/arxiv.2607.28128
q3 · i? · causal · r2
Deterministic manipulation check on the primary base with ten paired replicates; independence moved in the predicted direction but did not separate (P3 inconclusive), and probe accuracy saturated (0.77 to 1.00 across probe phases in all three conditions).
"ConvTutor’s mean per-session leakage fraction is 43.0% against 6.4% for PedTutor (P1 supported: paired difference+0.365, 95% CI[+0.217,+0.516], nine of ten replicate pairs; Table 2)."
Discussion¶
Related Claims¶
- On the primary base under the frozen Opus judge, ConvTutor and PedTutor do not differ significantly in judged helpfulness but are perfectly rank-separated in judged pedagogy — related
- On the primary base, a turn that leaks the answer predicts a higher Opus helpfulness rating and less next-turn independent student work — related
- Answer-revealing tutor turns are followed by less independent student work on every tutor base, a deterministic judge-invariant result — related
- A contingent tutor surrendered the full answer in one session in sixteen, against one in six for the question-only tutor — related
Page metadata
| Field | Value |
|---|---|
type |
claim |
id |
leakage-manipulation-check-probe-ceiling |
title |
The leakage manipulation fires: ConvTutor leaks far more than PedTutor on the primary base, while probe accuracy saturates and cannot distinguish conditions |
description |
The leakage manipulation fires: ConvTutor leaks far more than PedTutor on the primary base, while probe accuracy saturates and cannot distinguish conditions |
status |
review |
evidence_strength |
moderate |
newest_evidence |
2026 |
generated |
by process:wiki-ingest on 2026-10-11 |
trust |
unverified — no one has confirmed this page's content |
sources |
1 — shuyi-fan-2026 |
Frontmatter is the page's machine-readable record — see the Schema & Guide.