Claims

Only two of 37 objective assessment tools in minimally invasive gynecological surgery showed substantial evidence of validity

Claim · All claims
Evidence · 1 study · review r3 · q3
Currency · newest study 2024 · checked against its sources 2026-10-31 (automated, 1 of 1 entry) · not reviewed by a person · recheck by 2027: tool and model accuracy changes quickly

Subclaims

Reading the evidence codes

q is the design tier, i the impact, n the sample, and the kind with its r the rigour judged within that kind: what each code means.

This claim: no standardized effect is recorded in observations/ for it yet, so no benchmark reading is possible.

q3 i? Of 37 identified tools, only the procedure-specific OSA-TLH (manual) and the RobotiX Mentor simulator (APM) reached the substantial validity band (score 11–15); 17 tools showed moderate and 18 limited evidence. → Tesfai FM 2024

Evidence

Tesfai FM 2024

Tesfai FM, Nagi J, Morrison I, Boal M, Olaitan A, Chandrasekaran D, Stoyanov D, Lanceley A, Francis N. (2024). Objective assessment tools in laparoscopic or robotic‐assisted gynecological surgery: A systematic review. Acta Obstet Gynecol Scand. https://doi.org/10.1111/aogs.14840

q3 · i? · review · r3

Systematic review validity appraisal using a Messick-adapted scoring system (each aspect scored 0–3, maximum 15; 11–15 = substantial). Table 8 lists OSA-TLH and RobotiX Mentor simulator at score 11 as the only substantial-evidence tools; the review states "Only two tools showed substantive evidence of validity."

"Only two tools showed substantive evidence of validity. Reliability and validity per tool were provided."

Discussion

Page metadata