Claims

PICO versus PICOS and SPIDER: PICO gave higher sensitivity and lower precision, but with different numbers of search blocks per model

Claim · All claims
Evidence · 1 study · review r3 · q2
Currency · newest study 2018 · not yet checked against its sources · not reviewed by a person

Subclaims

Reading the evidence codes

q is the design tier, i the impact, n the sample, and the kind with its r the rigour judged within that kind: what each code means.

This claim: no standardized effect is recorded in observations/ for it yet, so no benchmark reading is possible.

q2 i? In one observational comparison across CINAHL, Embase, and MEDLINE, PICO searches retrieved higher sensitivity and lower precision than PICOS and SPIDER searches, but the models used different numbers of search blocks (PICO: 3, PICOS: 4, SPIDER: 6), so the results are expected on that basis. → Mette Brandt Eriksen 2018

Evidence

Mette Brandt Eriksen 2018

Mette Brandt Eriksen, PhD; Tove Faber Frandsen, PhD. (2018). The impact of patient, intervention, comparison, outcome (PICO) as a search strategy tool on literature search quality: a systematic review. Journal of the Medical Library Association 106 (4). https://doi.org/10.5195/jmla.2018.345

q2 · i? · review · r3

Observational comparison (Methley et al., 2014) of identical search terms combined via PICO, PICOS, or SPIDER across PubMed, Embase, and CINAHL, yielding nine searches with relevance judged against inclusion criteria. Table 3 prints, e.g., PICO sensitivity of 77.78% in CINAHL versus 66.67% for PICOS and SPIDER. The review notes "as different numbers of search blocks were used for each model... these results are expected."

"Although hardly conclusive due to extremely limited data, the use of PICO as a search strategy tool resulted in higher sensitivity and lower precision than the use of PICOS and SPIDER."

Discussion

Page metadata
Field Value
type claim
id pico-vs-picos-spider-blocks-confound
title PICO versus PICOS and SPIDER: PICO gave higher sensitivity and lower precision, but with different numbers of search blocks per model
description PICO versus PICOS and SPIDER: PICO gave higher sensitivity and lower precision, but with different numbers of search blocks per model
status review
evidence_strength weak
newest_evidence 2018
generated by process:wiki-ingest on 2026-10-16
trust unverified — no one has confirmed this page's content
sources 1 — mette-brandt-eriksen-2018

Frontmatter is the page's machine-readable record — see the Schema & Guide.