Robotic VR simulator performance is positively correlated with intraoperative performance, with a pooled correlation of r = 0.67 (95% CI 0.22 to 0.88)¶
Claim · All claims
Evidence · 1 study · quant-synthesisr1·q3·i3large
Currency · newest study 2021 · not yet checked against its sources · not reviewed by a person · overdue for a recheck since 2024: tool and model accuracy changes quickly
Subclaims¶
Reading the evidence codes
q is the design tier, i the impact, n the sample, and the kind with its r
the rigour judged within that kind: what each code means.
This claim: no standardized effect is recorded in observations/ for it yet, so no benchmark reading is possible.
q3 i3 A random-effects meta-analysis of three cross-sectional studies found a positive pooled correlation (r = 0.67, 95% CI 0.22 to 0.88) between robotic VR simulator performance and intraoperative performance, with substantial heterogeneity. → Schmidt MW 2021
Evidence¶
Schmidt MW 2021¶
Schmidt MW, Köppinger KF, Fan C, Kowalewski K-F, Schmidt LP, Vey J, Proctor T, Probst P, Bintintan VV, Müller-Stich B-P, Nickel F. (2021). Virtual reality simulation in robot-assisted surgery: meta-analysis of skill transfer and predictability of skill. BJS Open. https://doi.org/10.1093/bjsopen/zraa066
q3 · i3 · quant-synthesis · r1
Meta-analysis of three cross-sectional predictability studies (59 participants total) pooling correlation coefficients via Fisher's z-transformation with inverse-variance weighting. The pooled correlation was "r = 0.67, 95 per cent c.i. 0.22 to 0.88", with substantial heterogeneity between studies.
"Random-effects meta-analysis based on Fisher’s z-transformation of correlation coefficients revealed a positive pooled correlation (r = 0.67, 95 per cent c.i. 0.22 to 0.88) between robotic VR simulator performance (combined over all tasks assessed) and intraoperative performance"
Discussion¶
Related Claims¶
- Correlations between simulator task performance and intraoperative GEARS domains vary by task, and one study found no correlation between dVSS scores and intraoperative GEARS scores — a narrower finding that bears on this claim
- Virtual reality simulator performance has limited correlation with intraoperative robotic hysterectomy performance. — reports the opposite
- Hung et al. found a high correlation between GEARS scores for a simulated robotic partial nephrectomy and GEARS scores for the procedure on a live porcine model — a narrower finding that bears on this claim
Page metadata