Claims

Training on a simple low-fidelity 'choose-the-hole' bench model transferred to real clinical fibreoptic intubation performance in an RCT

Claim · All claims
Evidence · 1 study · review r3 · q3
Currency · newest study 2026 · not yet checked against its sources · not reviewed by a person

Subclaims

Reading the evidence codes

q is the design tier, i the impact, n the sample, and the kind with its r the rigour judged within that kind: what each code means.

This claim: no standardized effect is recorded in observations/ for it yet, so no benchmark reading is possible.

q3 i? In an RCT, participants who trained on the 'choose-the-hole' bench model significantly outperformed those receiving didactic teaching alone in a real clinical environment. → McCarthy Roisin 2026

Evidence

McCarthy Roisin 2026

McCarthy Roisin, Maher Liam, O'Dea Angela. (2026). Validation status of definitive airway management simulators: a systematic review. BJA: British Journal of Anaesthesia. https://doi.org/10.1016/j.bja.2026.01.027

q3 · i? · review · r3

Review synthesis of Naik (2001), a randomised trial of a low-fidelity bench model for fibreoptic manipulation skills (24 novices per Table 2), demonstrating predictive validity. Clinical testing occurred within one week of simulator training.

"In this RCT, participants who trained on the model significantly outperformed those receiving didactic teaching alone in a real clinical environment."

Discussion

Page metadata
Field Value
status review
generated by process:wiki-ingest on 2026-10-31
trust unverified — no one has confirmed this page's content

Frontmatter is the page's machine-readable record — see the Schema & Guide.