The most common use of gesture-based COTS devices in surgery was image manipulation in interventional radiology environments or the operating room (42 studies), followed by virtual or augmented reality for educational or interventional purposes (16 studies)¶
Claim · All claims
Evidence · 1 study · reviewr3·q3
Currency · newest study 2019 · not yet checked against its sources · not reviewed by a person
Subclaims¶
Reading the evidence codes
q is the design tier, i the impact, n the sample, and the kind with its r
the rigour judged within that kind: what each code means.
This claim: no standardized effect is recorded in observations/ for it yet, so no benchmark reading is possible.
q3 i? Image manipulation in interventional radiology or operating room environments was the most frequent use of gesture-based COTS devices, reported in 42 of the included studies. → Alvarez-Lopez F 2019
Evidence¶
Alvarez-Lopez F 2019¶
Alvarez-Lopez F, Maina MF, Saigí-Rubió F. (2019). Use of Commercial Off-The-Shelf Devices for the Detection of Manual Gestures in Surgery: Systematic Literature Review. Journal of Medical Internet Research. https://doi.org/10.2196/11925
q3 · i? · review · r3
The review's Table 5 taxonomy of uses of gesture-based COTS devices in surgery lists image manipulation as the largest category with N=42 studies, ahead of virtual or augmented reality for educational or interventional purposes (N=16) and robotic surgery (N=7).
"Manipulation of images in interventional radiology environments or in the operating room (N=42)"
Discussion¶
Related Claims¶
- Microsoft Kinect and the Leap Motion Controller were the most widely used COTS gesture-detection devices in surgical research, appearing in 50% and 36% of the 86 included studies respectively
- A randomized controlled trial found immersive virtual reality surgery training improved the knowledge and self-confidence of surgical residents
- In a 42-participant field study, Microsoft Kinect was found more useful and easier to use than the Leap Motion Controller, while the Leap Motion Controller was more accurate for manipulating CT images
- Finger-motion sensor (Leap Motion Controller) operation of angiographic and radiological images was significantly faster than mouse-based operation in observational studies with radiologists and dental students
- Significant patient-safety improvements were found in 80% of comparative virtual reality simulation studies for cataract surgery training — related
Page metadata